The fault name
Phase L3 Undervoltage
Fault code
102
Number of flashing red lights
2
Troubleshooting and illustration
1.Check the voltage between the AC input line L3 and N.
2.When the voltage between L3 and N is lower than 190V, the fault is reported.
3.Measurement input voltage L3 and N value is about 230V this fault is eliminated.
The fault name
phase L3 overvoltage
Fault code
101
Number of flashing red lights
1
Troubleshooting and illustration
1.Check the voltage between the AC input line L3 and N.
2.When the voltage between L3 and N exceeds 264V, the fault is reported.
3.Measurement input voltage L3 and N value is about 230V this fault is eliminated.